Residential HVAC Design
Room-by-room loads, equipment checked against manufacturer data, and ducts sized to deliver it — prepared in Wrightsoft Right-Suite Universal for permits, contractors and builders across the US.
The IRC and IECC require residential heating and cooling equipment to be sized with ACCA Manual S, based on loads from ACCA Manual J, and many building departments now ask for the reports with the mechanical permit. We prepare all three procedures — Manual J, Manual S and Manual D — in Wrightsoft Right-Suite Universal, as one consistent set built from your drawings, not from rules of thumb.
Room-by-room heating and cooling loads, sensible and latent, from your plans, window schedule and insulation specification — with design conditions, infiltration and duct location set to match the site and the energy code.
Furnaces, air conditioners and heat pumps checked against the manufacturer’s expanded performance data at your design conditions — total, sensible and latent capacity, sizing limits, heat pump balance point and backup heat.
Room airflows, available static pressure, total effective length and friction rate worked through to trunk and branch sizes, with velocity checks and a duct layout drawn on your floor plan.
Load calculations for existing homes moving to heat pumps, including cold-climate units — so the new system is sized to the house as it is now, not to the oversized furnace it replaces.
REScheck envelope compliance alongside the load calculations, with consistent areas, U-factors and climate zone, so the energy code report and the HVAC design tell the permit reviewer the same story.
Production-builder plan sets with several house types or orientations, duplexes and townhouses, additions, garage conversions and accessory dwelling units — one set of calculations per plan, ready to reuse.
All calculations are prepared in Wrightsoft Right-Suite Universal, ACCA-approved software for Manual J, S and D. You receive PDF reports with the project and design conditions, construction and window inputs, room-by-room loads, whole-house totals, the equipment selection check and the duct sizing — plus the duct layout drawing where Manual D is included.
To get started, send: floor plans and elevations (PDF or CAD), the site address, window and door schedule, insulation levels, and your preferred equipment type or model if one has been chosen.
Each project is quoted from the drawings, based on the number of plans and which of Manual J, S and D are required. Ongoing builder work can run on our hourly rate or package. Where a jurisdiction requires the reports to be signed by a licensed engineer or contractor, we prepare them for that person’s review and signature.