Choosing Glazing: U-Factor, SHGC and Visible Transmittance Explained

Glazing selection U-factor SHGC and visible transmittance
Three numbers on one label decide how much heat, sun and daylight a window lets through.

Windows are the weakest part of almost every building envelope. A good wall loses heat at a fraction of the rate of even a good window, and the window is also where the sun gets in. Choosing glazing therefore has a large effect on heating, cooling, comfort and daylight. Three numbers describe most of that effect: U-factor, solar heat gain coefficient (SHGC) and visible transmittance (VT).

U-factor: heat flow through the window

U-factor measures how much heat passes through the window for each degree of temperature difference between inside and outside. Lower is better. In US units it is given in Btu/h·ft²·°F, elsewhere in W/m²K. A single clear pane is very poor. Double glazing with a low-emissivity (low-E) coating and argon fill is far better, and triple glazing better again.

U-factor matters most when the temperature difference is large for long periods: heating in cold climates and, to a lesser degree, cooling in very hot ones. It also sets the inside surface temperature of the glass, which drives cold downdraughts and condensation in winter.

SHGC: heat from the sun

SHGC is the fraction of solar radiation striking the window that ends up as heat inside, between 0 and 1. Lower means less solar heat. In cooling-dominated buildings it is often more important than U-factor, because solar gain through glass is usually the largest single cooling load. In cold climates a higher SHGC on south-facing windows can be useful, because winter sun offsets heating.

VT: daylight

Visible transmittance is the fraction of visible light that passes through. Higher means more daylight and a clearer view. Early ways of cutting solar heat, such as dark tints and reflective coatings, also cut daylight, which led to darker rooms and more electric lighting. A low SHGC is only half the goal. The other half is keeping VT high enough for good daylight performance.

Light-to-solar-gain ratio

The ratio of VT to SHGC shows how well a glass separates light from heat. Modern spectrally selective low-E coatings pass most visible light while blocking much of the infrared part of sunlight. Glass with a ratio of 1.25 or more is generally described as spectrally selective. In hot, sunny climates this is often the most cost-effective glazing upgrade available, because it reduces cooling without darkening the space.

Centre-of-glass versus whole window

Glass manufacturers often quote centre-of-glass values, measured away from the edges. A real window also has a frame and a spacer at the glass edge, and both conduct more heat than the glass. The whole-window U-factor is usually noticeably worse than the centre-of-glass figure, especially with aluminium frames without thermal breaks. Energy codes and compliance tools use whole-window values, such as NFRC-rated values in the US. Check which one a data sheet gives before entering it in a model. For detailed frame and edge analysis, see window thermal analysis in WINDOW and THERM.

Priorities by climate

Orientation matters within a single building. Different glass on different facades is common in well-designed projects, though it adds procurement and appearance questions.

Glazing area matters as much as glazing type

The best glass cannot make up for too much of it. Prescriptive energy codes cap the window-to-wall ratio, commonly at 40% in ASHRAE 90.1. Larger glazed areas usually require a performance path such as an Appendix G energy model. Overheating rules such as Part O in England limit glazing area for the same reason.

Testing options in a model

A glazing study in an energy model compares options on several results at once: annual heating and cooling, peak cooling load and chiller or equipment size, comfort near the facade, and daylight. The cheapest glass on purchase price is not always the cheapest overall if it increases plant size or electric lighting.

The takeaway

Read all three numbers, use whole-window values, and choose for the climate and the orientation. In hot climates, look for low SHGC with high VT. In cold climates, start with a low U-factor. Then test the options in a model before committing, because glazing affects loads, comfort and daylight together.