Every new non-domestic building in England must show that it meets Part L of the Building Regulations. The proof is a calculation, and there are two approved ways to run it: SBEM, the Simplified Building Energy Model, and DSM, dynamic simulation modelling. Both produce the same compliance report. They differ in method, effort and how well they represent complex buildings.
What the calculation compares
Both tools follow the National Calculation Methodology. The software builds a notional building: the same size, shape and use as the real design, but with a fixed specification for fabric and services. The notional building's performance sets the targets. The actual design must do at least as well on two measures:
- Carbon emissions — the building emission rate must not exceed the target emission rate.
- Primary energy — the building primary energy rate must not exceed its target. This second test was added in the 2021 edition.
The result is issued as a BRUKL report, which also checks limiting fabric values, minimum services efficiencies and solar gain limits. It is produced at design stage and again as built, with the measured air permeability. The same model normally produces the Energy Performance Certificate.
How SBEM works
SBEM was developed by BRE for the government and is free to use through its interface, iSBEM, or through commercial front ends. It calculates energy use month by month using a quasi-steady-state method. Zones are defined by activity, and each is assigned HVAC, lighting and hot water systems from standard lists.
Its strengths are speed, low cost and consistency. For a simple shop, warehouse, small office or surgery, SBEM gives a sound compliance result with modest effort.
How DSM works
Dynamic simulation calculates heat flows hour by hour through the year using approved software. The geometry is modelled in three dimensions, so shading, solar gains and thermal mass are calculated directly. HVAC systems and controls can be represented in more detail.
The same notional building and the same standard activity schedules apply, so DSM is not a looser test. It is a more detailed calculation of the same question.
When DSM is the better choice
- Complex form and glazing — atria, heavy shading, curved or highly glazed facades, where solar gain matters hour by hour.
- Thermal mass and night cooling — strategies whose benefit a monthly method cannot see.
- Natural and mixed-mode ventilation with automatic control.
- Advanced systems — displacement ventilation, chilled beams, heat recovery between zones and similar.
- Tight margins — when SBEM shows a narrow fail, a more detailed model sometimes shows a fair pass because features are properly credited.
- Other studies needed anyway — if the project requires overheating, daylight or loads analysis, one dynamic model can serve all of them.
For Energy Performance Certificates, the most complex buildings are classed as Level 5 and must be assessed with DSM.
What neither tool tells you
Both methods use standard occupancy, setpoints and hours for each activity type. They exist so that buildings can be compared fairly, and they exclude most equipment loads. The result is a compliance figure and not a prediction of energy bills. A design-stage operational energy estimate, such as a CIBSE TM54 study, is a separate exercise with real hours and loads.
Practical advice
Run the calculation early, before the fabric and services specification is fixed. The 2021 targets are demanding, and passing usually needs a combination of good fabric, efficient heat pumps or similar low-carbon heating, efficient lighting with controls, and often photovoltaics. Check thermal bridging assumptions and make sure the air permeability target is one the contractor can meet.
The takeaway
SBEM is the efficient choice for simple buildings. DSM is the right choice where form, mass, ventilation strategy or systems are beyond what a monthly method can represent, or where margins are tight. Either way the target is the same: beat the notional building on carbon and primary energy, and show it in the BRUKL.
Need a Part L2 calculation or BRUKL report?
We prepare SBEM and dynamic simulation compliance calculations for non-domestic buildings, from design-stage BRUKL to as-built submission. Let's talk.
Get in touchThis article is general guidance and reflects information available at the time of writing. Requirements differ between England, Wales, Scotland and Northern Ireland and are updated periodically — always confirm the current Approved Document and approved software versions.